Penggunaan Metode Rolling Sphere untuk Pengamanan Jaringan 150 kV dari Sambaran Petir Langsung
DOI:
https://doi.org/10.32492/jeetech.v4i1.4104Keywords:
Substation, Lightning, Lightning Mast, Rolling Sphere Method, Ground WireAbstract
Lightning strikes can cause protection failure at substations such as equipment damage at substations due to insulation failure or what is known as flashover. Because of that, a lightning strike protection system is needed to minimize the occurrence of direct lightning strikes to equipment and buses at the substation. This study discusses the modeling of the protection of the substation from direct lightning strikes using the rolling sphere method at the Wonosari-pedan 150 kV substation using lightning rod poles. The calculation results show that with the configuration of a lightning rod as high as 21 m and the use of a ground wire of 17.8 m it meets the safe criteria for the height of the protected area in the case study of this research.
References
Rahmad Dwi Prima, Yul Martin, Endah Komalasari.,” Analisis Perbandingan Shielding Gardu Induk Menggunakan Model Electrogeometric”. Teknik Elektro Fakultas Teknologi Industri, Universitas Lampung, 2015.
Ugahari,Yudi. “Analisa Proteksi Sambaran Petir Eksternal Menggunakan Metode Collection Volme (Studi Kasus Gedung Fakultas Teknik Universitas Indonesia)”. Depok : Universitas Indonesia. 2008.
Mulyadi, Ujang. “Kajian Perancangan Sistem penangkal Petir Eksternal Pada Gedung Pusat Komputer Universitas Riau”. Universitas Riau. Pekanbaru, 2014.
Putra P Widhya., “Evaluasi sistem proteksi petir pada base tranciver station (bts)”, Departemen Teknik Elektro, Universitas Indonesia, Depok, 2009.
Pasra, N., Makulau, A., & Abriyanto, M. O. “Analisa Efek Korona Pada Sistem Distribusi Tenaga Listrik 20 kV Pada Gardu Beton”. SUTET, 8(2), 103-113. 2018
Kurniawan. Taufiq A., Sumadiyana. Achmad B., “Sistem Proteksi Petir Internal dan Eksternal”, Departemen Teknik Elektro, Universitas Indonesia, Jakarta, Oktober, 2007.
Dahliana, Nina., “Pemodelan Perlindungan Gardu Induk dari Sambaran Petir Langsung di PT. PLN (Persero) Gardu Induk 150 kV Ngimbang-Lamongan”, Teknik Elektro Fakultas Teknologi Industri, Institut Teknologi Sepuluh Nopember, 2013.
IEEE Guide for Direct Lightning Lightning Stroke Shielding of Substations, IEEE Standard 998-1996.
Pribadi, Rendy Trias. "Analisa dan Perancangan Daerah Perlindungan Penangkal Petir Pada Gedung Islamic Center UIN Suska Riau." PhD diss., Universitas Islam Negeri Sultan Syarif Kasim Riau, 2017.
M. Ali, M. R. Djalal, S. Arfaah, Muhlasin, M. Fakhrurozi, and R. Hidayat, “Monitoring and Identification Electricity Load Using Artificial Neural Network,” in 2021 7th International Conference on Electrical, Electronics and Information Engineering (ICEEIE), IEEE, Oct. 2021, pp. 1–6. doi: 10.1109/ICEEIE52663.2021.9616922.
Machrus Ali, Dwi Ajiatmo, and Muhlasin, “Optimasi Kualitas Tenaga Listrik Di Area Banyuwangi Menggunakan Radio Gateway Over Internet Protocol,” J. JEETech, vol. 1, no. 2, pp. 70–77, Nov. 2020, doi: 10.48056/jeetech.v1i2.3.
Published
How to Cite
Issue
Section

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.