Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung

Authors

  • Rahmat Hidayat Institut Teknologi Nasional, Malang
  • Abraham Lomi Institut Teknologi Nasional, Malang
  • Irrine Budi Sulistiawati Institut Teknologi Nasional, Malang

DOI:

https://doi.org/10.32492/jeetech.v5i2.5202

Keywords:

Optimasi, Pembangkit Terdistribusi, Artificial Bee Colony, Rugi-rugi Daya, Distributed Generation

Abstract

Distributed Generation (DG) is a power plant that is spread over the power distribution network. In principle, electrical power output is generated by power plants located far from the load center and electrical power is transmitted to the load center through transmission and distribution networks. The longer the cable from the power plant or substation, the lower the voltage at the end load. Sub-optimal DG placement and size can result in increased power losses and affect the system voltage profile. In addition, suboptimal generation capacity can lead to voltage instability, reduced system security, and potential impacts on system frequency and emissions. Therefore, this study will use the Artificial Bee Colony (ABC) method to determine the optimal DG capacity and location. In the base case condition, the power losses in the system are 118 KW and 99 Kvar. Power losses after the installation of 1 DG active power loss becomes 37.4 KW and reactive power loss becomes 31.65 Kvar. Placement of 2 DGs reduces active power loss to 17 KW and reactive power loss to 15 Kvar. While the placement of 3 DG reduces active power loss to 33 KW and reactive power loss to 28 KVar.

References

N. I. Luthfi, Y. Yuningtyastuti, and S. Handoko, “Optimasi Penempatan Distributed Generation Pada Ieee 30 Bus System Menggunakan Bee Colony Algorithm,” Transient: Jurnal Ilmiah Teknik Elektro, vol. 2, no. 3, pp. 757–763, Nov. 2013, doi: 10.14710/TRANSIENT.V2I3.757-763.

I. Kholiq, “Analisis Pemanfaatan Sumber Daya Energi Alternatif Sebagai Energi Terbarukan untuk Mendukung Subtitusi BBM,” Jurnal IPTEK, vol. 19, no. 2, pp. 75–91, Dec. 2015, doi: 10.31284/J.IPTEK.2015.V19I2.12.

Presiden Republik Indonesia, Peraturan Pemerintah Republik Indonesia No. 79 Tahun 2014 tentang Kebijakan Energi Nasional. 2014.

Presiden Republik Indonesia, Peraturan Presiden No. 22 Tahun 2017 Tentang Rencana Umum Energi Nasional. 2017.

Y. Yanuar, A. Asmar, R. Kurniawan, “Analisis Perbaikan Drop Tegangan Dan Susut Jaringan Penyulang Jambi Pln Area Belitung Menggunakan Etap,” Proceedings Of National Colloquium Research And Community Service, vol. 1, 2017, doi: 10.33019/SNPPM.V1I0.512.

G. Pepermans, J. Driesen, D. Haeseldonckx, R. Belmans, and W. D’haeseleer, “Distributed generation: definition, benefits and issues,” Energy Policy, vol. 33, no. 6, pp. 787–798, Apr. 2005, doi: 10.1016/J.ENPOL.2003.10.004.

M. M. Aman, G. B. Jasmon, A. H. A. Bakar, and H. Mokhlis, “A new approach for optimum DG placement and sizing based on voltage stability maximization and minimization of power losses,” Energy Convers Manag, vol. 70, pp. 202–210, Jun. 2013, doi: 10.1016/J.ENCONMAN.2013.02.015.

F. S. Abu-Mouti and M. E. El-Hawary, “Optimal distributed generation allocation and sizing in distribution systems via artificial bee colony algorithm,” IEEE Transactions on Power Delivery, vol. 26, no. 4, pp. 2090–2101, Oct. 2011, doi: 10.1109/TPWRD.2011.2158246.

C. Das, O. Bass, G. Kothapalli, T. Mahmoud, D. H.-A. energy, and undefined 2018, “Optimal placement of distributed energy storage systems in distribution networks using artificial bee colony algorithm,” Elsevier, Accessed: Dec. 03, 2023. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S0306261918311358

I. Supartana, R. Hartati, and I. Sukerayasa, “Optimasi Titik Interkoneksi Distributed Gener-Ation (Pltm Muara) Guna Meminimalkan Rugi–Rugi Daya Menggunakan Metode,”

S. T. Wrahatnolo et al., Teknik Distribusi Tenaga Listrik. 2008.

P. Chary, T. Mahesh, … A. K.-2020 I., and undefined 2020, “Load flow analysis of radial distribution system,” ieeexplore.ieee.org

Hadi Saadat, Power System Analysis. New York: McGraw-Hill Inc, 1999.

L. Alkhawaldeh, “Impact of wind farms on harmonic distortion and voltage profiles in distribution systems.” Jan. 2023. doi: 10.13140/RG.2.2.14767.30882.

Syufrijal and R. Monantun, “Jaringan Distribusi Tenaga Listrik,” 2014.

T. Ackermann, G. Andersson, and L. Söder, “Distributed generation: a definition,” Electric Power Systems Research, vol. 57, no. 3, pp. 195–204, Apr. 2001, doi: 10.1016/S0378-7796(01)00101-8.

K. Ullah, Q. Jiang, G. Geng, S. Rahim, and R. A. Khan, “Optimal Power Sharing in Microgrids Using the Artificial Bee Colony Algorithm,” Energies 2022, Vol. 15, Page 1067, vol. 15, no. 3, p. 1067, Jan. 2022, doi: 10.3390/EN15031067.

F. Ratuhaji, A. Arief, M. N.-J. of P. Conference, and undefined 2019, “Determination of optimal location and capacity of distributed generations based on artificial bee colony,” iopscience.iop.orgF Ratuhaji, A Arief, MB NappuJournal of Physics: Conference Series, 2019•iopscience.iop.org, doi: 10.1088/1742-6596/1341/5/052012.

Published

2024-11-01

How to Cite

[1]
R. Hidayat, A. Lomi, and I. Budi Sulistiawati, “Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung”, jeetech, vol. 5, no. 2, pp. 113-125, Nov. 2024.