Frekuensi Gangguan dan Energi Tak Tersalurkan Sebagai Indikator keandalan Sistem Jaringan Tegangan Menengah

Authors

  • Rusliadi Rusliadi Politeknik Negeri Fakfak
  • Yulianto La Elo Politeknik Negeri Fakfak

DOI:

https://doi.org/10.32492/jeetech.v5i2.5208

Keywords:

FGTM, Energy Not Supplied, Keandalan Sistem Jaringan, SAIDI, SAIFI

Abstract

The increasing need for electrical energy must be balanced with improved customer service. Customers will feel comfortable if they can enjoy an uninterrupted electricity supply in the form of a disconnection of the electricity supply for a certain period of time or what is commonly called the ENS (Energy Not Supplied) index and the AENS (Average Energy Not Supplied) index. The reliability of the electric power system is one of the things that is very important in order to maintain the performance of the three main pillars of PT. PLN (Persero). A reliable distribution network can be seen from the number of disruptions that often occur in the distribution network. Disruptions that arise in the distribution network arise due to internal factors such as less reliable distribution network components. In addition, it can also be caused by external factors such as natural disasters or the influence of trees and animals. Based on the results of the research that has been conducted, it is known that the occurrence of disruptions and the length of the duration of the disruption cause the Energy Not Supplied (ENS) value to increase as in April and July, the high duration of the blackout also makes the ENS higher, namely 792.857804 kW and 789.046811 kW. However, the distribution network at the Wagom feeder is still considered reliable in distributing electrical energy based on the SAIDI and SAIFI indices. From the research results, the SAIDI index at the Wagom feeder reached 8.96 hours/customer/year. While the SAIFI index at the Wagom feeder reached 2.08 times/customer/year.

References

E. A. Joseph, Rangkaian Listrik. Edisi Kedua, 2nd ed. Jakarta: Erlangga, 1984.

Adibtyo Putro Gumilang, “PENILAIAN KEANDALAN SISTEM TENAGA LISTRIK JAWA BAGIAN TIMUR DAN BALI MENGGUNAKAN FORMULA ANALITIS DEDUKSI DAN SENSITIVITAS ANALITIS DARI EXPECTED ENERGY NOT SERVED,” Jurnal Teknik ITS, vol. 7, no. 1, 2018.

Hendy Susilo and Jatmiko, “Analisis Pemeliharaan Korektif Dan Preventif Pt Sinar Abadi Sukoharjo Dengan Pola Rincian Harga Satuan Di Wilayah Kerja Rayon Wonogiri,” Surakarta, 2018.

T. Gonen, Electric Power Distribution Engineering, 3rd ed. New York: CRC Press, 2015.

Andika, Dimas Aldi Yanuar, and Agus Supardi, “Pengaruh Pembebanan Terhadap Umur Transformator Tenaga di Gardu Induk Palur 150 kV,” Universitas Muhammadiyah Surakarta, Surakarta, 2018.

R. Berlianti and R. Fauzi, “Analisis Penerapan Tindakan Pemeliharaan Sistem Distribusi 20 kV Dalam Pengoptimalan ENS dan FGTM,” Jurnal Sain, Energi, Teknologi & Industri), vol. 5, no. 2, pp. 44–50, 2021.

Y. Christopel Aritonang, S. Yosafat Berutu, T. Listrik, T. Elektro, and P. Negeri Medan, “PENGARUH PEMELIHARAAN JARINGAN DISTRIBUSI TERHADAP ENERGY NOT SALE PADA PENYULANG GL.01 DI PLN HELVETIA.”

Y. Yolnasdi, E. Harda A, E. Ermawati, and C. Chrismondari, “Evaluasi Pemeliharaan Jaringan Distribusi Tegangan Menengah 20 KV Dalam Upaya Menekan Jumlah Energi Yang Tidak Tersalurkan Dan Frekuensi Gangguan Pada Penyulang Losari,” Sainstek (e-Journal), vol. 10, no. 1, pp. 17–23, Jun. 2022, doi: 10.35583/js.v10i1.4.

Adriani, “Analisis Faktor Penurunan Gangguan Saluran Udara Tegangan Menengah (SUTM) Pada Penyulang Parangbanoa,” Vertex Elektro, vol. 13, no. 1, pp. 1–8, 2021.

N. Muranto, “STUDI PERALIHAN DAYA LISTRIK DARI PLN KE GENERATOR SET (GENSET) KETIKA TERJADI PEMADAMAN DARI PLN DENGAN UNINTERRUPTIBLE POWER SUPPLY (UPS) PADA HOTEL GRAND ELITE PEKANBARU,” Jurnal Sain, Energi, Teknologi & Industri), vol. 3, no. 1, pp. 9–16, 2018.

Y. Tonce Kusuma Priyanto et al., “ANALISIS INDEKS SAIDI, SAIFI, CAIDI DAN NON-DELIVERY ENERGY SISTEM DISTRIBUSI 20 KV PADA PT. PLN (PERSERO) AREA BALIKPAPAN PENYULANG J2.”

Junto Dennis Haryantho and Hanny Hosiana Tumbelaka, “Analisa Keandalan Sistem Kelistrikan Di Daerah Pelayanan P.T. PLN (Persero) Area Timika Berbasis SAIDI SAIFI,” Jurnal Teknik Elektro, vol. 10, no. 2, 2017.

Published

2024-11-01

How to Cite

[1]
R. Rusliadi and Y. La Elo, “Frekuensi Gangguan dan Energi Tak Tersalurkan Sebagai Indikator keandalan Sistem Jaringan Tegangan Menengah”, jeetech, vol. 5, no. 2, pp. 173-180, Nov. 2024.